Home / UBY Environment / Wireless sound level meter – INFRA C50

Wireless sound level meter – INFRA C50

The INFRA C50 is a new generation of permanent noise monitoring station. Based on a Class 1 sound level meter with a robust MEMS microphone system, this noise station is designed for continuous environmental monitoring.

Technical Features

Sound level meter: IEC 61672–1:2013 Class 1 (approval pending)​

Data type: Two measurement ranges:​

  • 31 dB – 132 dB (lower power
    consumption)​
  • 26 dB – 123 dB.

Measurement ranges: Frequency range: 10 Hz – 20,000 Hz.​

Measurement frequency: Adjustable interval between 1 s and 1 h.​

Network: The system includes 4G wireless communication with 3G/2G fallback.​

Transmission frequency: Data files are saved to the memory card before being sent at the next cellular communication. If the point of communication is unavailable, data is stored for later transfer.​

Power supply: The C50 uses internal rechargeable lithium-ion batteries that can be swapped or charged during operation. As standard, it is supplied with a waterproof external power supply.​

Battery life: Up to 6 weeks of
operation.​

Dimensions: 650 mm x 99 mm x 95 mm
(25.6 x 4.0 x 3.7 in).​

Weight: 2.7 kg (5.9 lb) without batteries.​
With batteries included: 3.55 kg (7.8 lb).​

Weatherproofing: The waterproof housing protects the C50 noise monitoring station from extreme weather while meeting Class 1 metrological accuracy requirements.​ IP 65 protection rating.​

Mounting method and conditions: The C50 can be easily fixed to tripod or wall-mount supports using its 1/4” threaded plate. Quick-release mast
accessories can also be used.​

Technical Requirements and Maintenance

Maintenance: Calibration is recommended every year, and laboratory calibration every 2 years.